Thứ Sáu, 15 tháng 5, 2015

EE776 Riel | EE776 Insertion Thermal Flow meter | Pitesco vietnam


Measuring principle of heat loss
Measuring range 0.2 to 100 Nm/s or 0.2 to 200 Nm/s
Output signal 0 to 10 V - 0 to 20mA - 4 to 20mA
Process connection DN50 to DN300
Materials AISI3Cu custody - Stainless steel sensor - the sensor head PBT
Temperature up to 80 ° C - Pressure up to 16 bar




Liên hệ cho chúng tôi theo số: 0988 424 925 | 0916 597 556 để được tư vấn 
Email : nga@pitesco.com

Principle of measurement:Thermal dispersion mass  
Applicable fluid:
Compressed air, nitrogen, CO2, oxygen, helium other non-corrosive and non-flammable
Measuring Range:
DNStandard flowHigt flow
501.8÷8951.8÷1791
652.9÷14962.9÷2938
804.1÷20374.1÷4074
1006.9÷34386.9÷6876
12510.4÷520310.4÷10407
15015.3÷762815.3÷15257
20026.2÷1307526.2÷26150
25040.9÷2044940.9÷40898
30057.8÷2892057.8÷57840

Accuracy:± 2,5% reading or 0,5% full scale
Materials:
Housing: metal AISI1326-1
Probe: stainless steel
Sensor head: PBT
Ball valve: brass
Multi Controller: aluminium
Output signal:Voltage:  0÷10 V (max 1mA)
Current: 0÷20mA - 4÷20mA
Switching: Potential-free max. 44 VDC, 500mA
Pulse: totalizer, pulse length: 0.02÷2 sec.
Digital interface: USB (for configuration)
Temperature:Environment: -20÷60°C
Media: -20÷80°C
Nominal pressure:16 bar
Protection class:IP65
Input:4÷20mA  for precision sensor
Supply voltage:18÷30 V AC/DC 
Humidity:0÷99% RH no condensation
Optional:Optional pressure compensation